Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Arq. bras. cardiol ; 102(2): 181-186, 03/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-704613

ABSTRACT

Fundamento: Pacientes com insuficiência cardíaca (IC) apresentam disfunção ventricular esquerda e redução da pressão arterial média (PAM). O aumento do estímulo adrenérgico causa vasoconstrição e resistência dos vasos, mantendo a PAM, enquanto aumenta a resistência vascular periférica e a rigidez dos vasos condutores. O aumento da pressão de pulso (PP) reflete a complexa interação do coração com os sistemas arteriais e venosos. O aumento da PP é um importante marcador de risco em pacientes com insuficiência cardíaca crônica (ICC). A ventilação não invasiva (VNI) tem sido utilizada para IC aguda descompensada para melhorar a congestão e a ventilação pelos efeitos respiratórios e hemodinâmicos. No entanto, nenhum desses estudos relatou o efeito da VNI na PP. Objetivo: O objetivo deste estudo foi determinar os efeitos agudos da VNI com CPAP (pressão positiva contínua nas vias aéreas) sobre a PP em pacientes ambulatoriais com ICC. Métodos: Seguindo um protocolo randomizado, duplo-cego, cruzado e controlado com placebo, 23 pacientes com ICC (17 homens, 60 ± 11 anos, IMC 29 ± 5 kg/cm2, classes II e III da NYHA) foram submetidos à CPAP via máscara nasal durante 30 minutos na posição reclinada. A pressão da máscara foi de 6 cmH2O, enquanto o placebo foi fixado em 0-1 cmH2O. PP e outras variáveis hemodinâmicas não invasivas foram avaliadas antes, durante e depois do placebo e do modo CPAP. Resultados: A CPAP diminuiu a frequência cardíaca de repouso (pré: 72 ± 9; pós 5 min: 67 ± 10 bpm , p < 0,01) e PAM (CPAP: 87 ± 11; controle 96 ± 11 mmHg , p < 0,05 pós 5 min). A CPAP diminuiu a PP (CPAP: 47 ± 20 pré para 38 ± 19 mmHg pós; controle: ...


Background: Patients with heart failure (HF) have left ventricular dysfunction and reduced mean arterial pressure (MAP). Increased adrenergic drive causes vasoconstriction and vessel resistance maintaining MAP, while increasing peripheral vascular resistance and conduit vessel stiffness. Increased pulse pressure (PP) reflects a complex interaction of the heart with the arterial and venous systems. Increased PP is an important risk marker in patients with chronic HF (CHF). Non-invasive ventilation (NIV) has been used for acute decompensated HF, to improve congestion and ventilation through both respiratory and hemodynamic effects. However, none of these studies have reported the effect of NIV on PP. Objective: The objective of this study was to determine the acute effects of NIV with CPAP on PP in outpatients with CHF. Methods: Following a double-blind, randomized, cross-over, and placebo-controlled protocol, twenty three patients with CHF (17 males; 60 ± 11 years; BMI 29 ± 5 kg/cm2, NYHA class II, III) underwent CPAP via nasal mask for 30 min in a recumbent position. Mask pressure was 6 cmH2O, whereas placebo was fixed at 0-1 cmH2O. PP and other non invasive hemodynamics variables were assessed before, during and after placebo and CPAP mode. Results: CPAP decreased resting heart rate (Pre: 72 ± 9; vs. Post 5 min: 67 ± 10 bpm; p < 0.01) and MAP (CPAP: 87 ± 11; vs. control 96 ± 11 mmHg; p < 0.05 post 5 min). CPAP decreased PP (CPAP: 47 ± 20 pre to 38 ± 19 mmHg post; vs. control: 42 ± 12 mmHg, pre to 41 ± 18 post p < 0.05 post 5 min). Conclusion: NIV with CPAP decreased pulse pressure in patients with stable CHF. Future clinical trials should investigate whether this effect is associated with improved clinical outcome. .


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Blood Pressure/physiology , Continuous Positive Airway Pressure/methods , Heart Failure/physiopathology , Heart Failure/therapy , Noninvasive Ventilation/methods , Analysis of Variance , Body Mass Index , Chronic Disease , Cross-Over Studies , Double-Blind Method , Hemodynamics , Reproducibility of Results , Statistics, Nonparametric , Time Factors , Treatment Outcome , Ventricular Dysfunction, Left/physiopathology
2.
J. bras. med ; 81(5/6): 42-45, nov.-dez. 2001. ilus, tab
Article in Portuguese | LILACS | ID: lil-304991

ABSTRACT

Os autores apresentam um caso de comunicação interatrial (CIA) tipo seio venoso em mulher de 60 anos, portadora de doença pulmonar obstrutiva crônica (DPOC) severa evoluindo com síndrome de Eisenmenger. Ressaltam a necessidade de diagnóstico prococe e tratamento adequado, capazes de evitar a evolução desfavorável, e chamar a atenção para a complementação diagnóstica com ecocardiograma transesofágico


Subject(s)
Humans , Eisenmenger Complex , Heart Septal Defects, Atrial , Heart Defects, Congenital
SELECTION OF CITATIONS
SEARCH DETAIL